Consulting Engineers
Ingenium Engineering provides mechanical, electrical, and plumbing consulting engineering services for commercial, industrial, and residential clients. Our mission is to provide clients with quality, cost effective designs based on sound engineering practices, in line with their project needs and schedules.
Our firm has experience providing engineering services both as sub and prime-consultants. Prior project types include public schools, car dealerships, retail build-outs, office spaces, doctors offices, distribution warehouses, industrial plant processes, hotels, condos, product approvals submissions, and restaurants.
Ingenium Engineering has a multitude of experience which allows us to accommodate a wide variety of project types which range from small one page projects to large scale, complex projects, with large engineering demands.
Mechanical Design
HVAC Design
Chilled water system design
Fire sprinkler system design
Heat load calculations
Head loss calculations
Ducts supply and exhaust system design
Chiller and cooling tower system design
Piping system design
Wind load and tie down calculations
Finite Element Analysis for heat transfer, loading, fatigue, and fluid flow
Product approval (Miami Dade & Florida NOA) analaysis document preparation.
Electrical Design
Electrical power and lighting distribution system design
Fire alarm system design
Generator system design
Solar system design
Load studies
Photometric calculations and onsite analysis
Arc flash studies and analysis
Short circuit analysis
Plumbing Design
Sanitary piping system design
Cold and hot water piping system design
Indirect waste piping system design
Gas piping system design and calculations
CW booster pump design
Piping friction loss calculations
Roof drain piping system design
Other Services
30/40 Year Building Inspections
Metal fabrication design and calculations
Swimming pool design for commercial and residential pools
Residential projects
We have provided MEP design services on countless residential projects ranging from single family home renovations/additions, condos, new custom homes, to complete tear down rebuilds.
Prior Projects
Everglades High School HVAC renovation
Client: Broward County School Board
Engineer of record responsible for replacement of two 400 ton water cooled chillers, piping, campus heat load calculation to verify chiller size, exhaust fan replacement. Provided MEP design drawings and calculations.
Miramar Elementary School HVAC renovation
Client: Broward County School Board
Engineer of record responsible for replacement of two 200 ton air cooled chillers, chilled water pumps, chilled water piping system, 38 fan coil units, heat load calculations, piping head loss calculations. Provided MEP design drawings and calculations.
Car dealership renovation
Client: Coconut Creek Hyundai and Genesis
A/C equipment and duct replacement for showroom and office renovations. Mechanical and pluming plans for new shop.
Car dealership renovation
Client: Deerfield Hyundai
A/C equipment and duct replacement for showroom and office renovation. Mechanical and pluming plans for new shop.
Cold warehouse storage and office HVAC renovation
Client: Goldcoast Beverage, Doral FL
Converted ammonia chiller system to DX rooftop systems serving 300,000 square foot of cold storage space (65°F) and replacing air handing units serving 150,000 square foot of office space. Provided MEP design drawings and calculations.
Retail build out – 28 spaces
Client: Atlas Business Center, Hollywood FL
Phase I (shell) and phase II (tenant build out) MEP design drawings and calculations. Replace existing electrical service with new 2200 amp service and switchgear. Heat load calculations for all spaces. Exposed duct design for all spaces.
Dr. Office build out
Client: Smitter, Jupiter FL
Mechanical and plumbing design drawings and calculations. All new duct system, add bathrooms, sinks, water heaters.
Industrial cooling process
Client: Panda Generators, Pompano Beach FL
Engineer of record charged with designing a cooling system to cool multiple generators being tested. Cooling tower, storage tank, pump, piping, and controls. Also added a backup generator to the 50,000 SF building.
Industrial process plant install
Client: Tropical Roofing, Hallandale FL
Engineer of record responsible for designing a silicon manufacturing plant with an industrial chiller to cool mixing process, office space, raw material tank installation and piping, compressed air piping design, exhaust system design, machine vibration analysis and equipment base design, design and analysis of custom ship ladder. Provided MEP design drawings and calculations.
Boeing training facility arc flash study
Client: Boeing, Doral FL
Executed an arc flash study to update arc flash labels throughout the flight simulator training facility. 4000 amp service.